SIMARINE logo

Call to order

Simarine SI-ST107 Tank Module

SKU: SIST107

CALL FOR PRICING & AVAILABILITY - (02) 4257-2636

Shipping information

We offer fast and reliable shipping options to ensure that your order arrives in a timely manner. Our dedicated team works diligently to process and ship your items as quickly as possible.

Here are some key points to note about our shipping policy:

Standard Shipping

  • Frankies offers a $15.95 flat rate for Australia-wide shipping, no matter how many items you order. Some larger or heavier items may incur an additional fee, which will be communicated to you when your order is processed.
  • While we endeavour to dispatch all orders promptly, please be advised that due to the current national fuel shortages in Australia and the resulting pressure on logistics networks, order processing and dispatch may take up to 7 business days. We are not liable for delays caused by third-party freight carriers or fuel-related logistical disruptions. By placing an order, you acknowledge that delivery timeframes may be extended beyond our standard estimates during this period.

Estimated delivery times:

  • WA, NT, and TAS: currently experiencing longer shipping times
  • Holiday periods (e.g. Christmas): deliveries may be delayed due to increased freight volumes

Express Shipping

  • Express shipping is available and calculated based on your delivery location, as well as the size and weight of your order. To receive an accurate quote, please contact our Albion Park Rail store and request an "express shipping quote." Our team will promptly assist with pricing and availability. Payment for express shipping can be securely arranged over the phone.

Product features

Designed to Work With Wide Connection & Monitoring!

Fresh, Gray or Black – keep your waters under control with ST107 module.

ST107 is an the ultimate digital module, that allows wide connection (and monitoring) possibilities. It enables monitoring tank levels (up to 7x), battery voltages (up to 3x), temperatures (up to 4x).

Operating

  • Power source voltage range 6 – 35 V
  • Temperature range - 20 – +70 °C
  • Power consumption at 12 V
  • Operating 3,5 mA
  • Voltage measuring channels 3
  • Resistive measuring channels 4
  • Relay (monostable)
  • Maximum Operating Current 1 A
  • Maximum Common Input Voltage 6 – 30V

Voltage inputs

  • Range 0 – 75 V
  • Resolution 1 mV
  • Accuracy ± 0,2 %
  • Sampling rate 100 ms
Resistance inputs
  • Range 0 Ohm – 65 kOhm
  • Accuracy ± 3,0%

Connectivity Up to

  • Voltage sensors (voltage drop/tank level) 3
  • Resistive inputs (tank level/temperature) 4
  • Relay Common Input (COM) 1
  • Relay Output Normally Open (NO) 1
  • Relay Output Normally Closed (NC) 1
  • SiCOM RJ 9 Sockets 2

Installation and Dimension

  • Dimensions (Length x Width x Depth) 110mm x 70mm x 30mm
  • Battery Connection M10 Bolts