{"product_id":"dna-cbm150y-150a-manual-reset-circuit-breaker-12-48v-dc-ip67","title":"DNA CBM150Y 150A Manual Reset Circuit Breaker 12-48V DC IP67","description":"\u003ch2 dir=\"auto\" class=\"text-text-100 mt-3 -mb-1 text-[1.375rem] font-bold\"\u003e\u003cstrong\u003eDNA CBM150Y 150A Manual Reset Circuit Breaker 12-48V DC IP67 Waterproof\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eA 150A manual reset circuit breaker from DNA, the CBM150Y operates across 12-48V DC with IP67 waterproof protection, ignition-safe design (no spark or heat during use), and 6mm studs for termination with 8-6 or 22-6 lugs, suited to automotive, marine, caravan, and 4WD electrical system protection applications.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eThe DNA CBM150Y is a 150A manual reset circuit breaker designed for use in 12V, 24V, and 48V DC electrical systems including vehicles, caravans, marine installations, and dual battery setups. The IP67 waterproof rating confirms full protection against dust and temporary immersion, making it suited to exposed installation positions in engine bays, under-vehicle locations, and marine environments. The ignition-protected design ensures no sparking or heat generation during operation, a critical safety requirement for installation near fuel systems and in confined spaces. The 6mm studs are compatible with 8-6 or 22-6 crimp lugs for a clean and secure wiring termination.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eManual reset operation allows the circuit breaker to be reset by hand after a trip event rather than requiring replacement, providing a reusable protection solution for main power feed and sub-circuit protection in complex 12-48V DC electrical builds.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003e\u003cstrong\u003eFeatures \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003e150A Rating - 12-48V DC Operation:\u003c\/strong\u003e Rated at 150A across 12V, 24V, and 48V DC systems, covering passenger vehicles, commercial vehicles, caravans, 4WDs, and marine applications with a single circuit breaker unit.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eManual Reset - Reusable Protection:\u003c\/strong\u003e Manual reset operation allows the breaker to be reset by hand after a trip event, providing reusable circuit protection without requiring replacement after each fault.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eIP67 Waterproof - Engine Bay and Marine Ready:\u003c\/strong\u003e IP67 rated for full dust protection and temporary water immersion, enabling installation in engine bays, exposed exterior locations, and marine environments without additional waterproofing.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eIgnition Protected - No Spark or Heat During Use:\u003c\/strong\u003e The ignition-protected design produces no sparking or heat during operation, meeting safety requirements for installation near fuel systems and in confined or flammable environments.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003e6mm Studs - Compatible with 8-6 and 22-6 Lugs:\u003c\/strong\u003e The 6mm stud terminals accept standard 8-6 or 22-6 crimp lugs for a clean, secure, and vibration-resistant wiring termination.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003e\u003cstrong\u003eTechnical Specs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"overflow-x-auto w-full px-2 mb-6\"\u003e\n\u003ctable class=\"min-w-full border-collapse text-sm leading-[1.7] whitespace-normal\"\u003e\n\u003cthead class=\"text-left\"\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"text-text-100 border-b-0.5 border-[hsl(var(--border-300)\/0.6)] py-2 pr-4 align-top font-bold\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eSKU\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCBM150Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eDNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eType\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eManual Reset Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eRating\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e12-48V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eIgnition Protected\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eYes (No Spark or Heat)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eStud Size\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eCompatible Lugs\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003e8-6 or 22-6 Crimp Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eReset Type\u003c\/td\u003e\n\u003ctd class=\"border-b-0.5 border-[hsl(var(--border-300)\/0.3)] py-2 pr-4 align-top\"\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"auto\" class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003e\u003cstrong\u003eCompatible With\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eThe CBM150Y is compatible with 12V, 24V, and 48V DC electrical systems. The 6mm studs accept 8-6 or 22-6 crimp lugs for termination. Confirm the required amperage rating and system voltage against your specific electrical installation before purchase.\u003c\/p\u003e\n\u003ch3 dir=\"auto\" class=\"text-text-100 mt-3 -mb-1 text-[1.125rem] font-bold\"\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eIs the CBM150Y suitable for marine installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eYes. The IP67 waterproof rating and ignition-protected design make the CBM150Y suitable for marine installation in exposed positions.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eDoes the CBM150Y need to be replaced after a trip event?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eNo. The manual reset design allows the breaker to be reset by hand after a trip event and reused without replacement.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eWhat lug size is compatible with the CBM150Y studs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eThe 6mm studs are compatible with 8-6 or 22-6 crimp lugs for termination.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003e\u003cstrong\u003eIs the CBM150Y suitable for 24V and 48V systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal\" dir=\"auto\"\u003eYes. The CBM150Y operates across 12-48V DC, covering 12V, 24V, and 48V electrical systems.\u003c\/p\u003e","brand":"DNA","offers":[{"title":"Default Title","offer_id":44794537246813,"sku":"CBM150Y","price":45.95,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0640\/9528\/9437\/files\/CBM150Y-1.webp?v=1785191964","url":"https:\/\/frankiesautoelectrics.com.au\/products\/dna-cbm150y-150a-manual-reset-circuit-breaker-12-48v-dc-ip67","provider":"Frankies Auto Electrics","version":"1.0","type":"link"}